If an error condition is encountered the error messages are as follows :-
`ERR1:Plane IJK has not been defined. Use CON SHAP PLA IJK to define IJK directions.' `ERR2:No body with the IJK definition points has been found. Check IJK plane only contains points on one body.' `ERR3:No surfaces have been defined. Model must be of the wrong type.' `ERR5:No K defining point found on the body containing the I and J definitions. Check IJK plane definition.' `ERR6:No Bodies found. Check the geometry.' `ERR8:Not all the bodies found have been connected. Check that the bodies are stacked as directed in the manual.' `ERR9:Number of divisions/layer exceeds maximum allowed. The size of array IDIVMX needs increasing.' `ERR10:The bodies are not all IJK regular. See the manual for more details.' `ERR11:No Mesh exists. Generate a mesh using MESH GENERATE and then try again.' `ERR12:The number of nodes per element is not eight. Check element type is QU8 using LABEL GEO TYPE.' `ERR13:No bodies have been defined. If the problem is 2D sweep the surfaces to create bodies.' `ERR14:The number of bodies found is more than the maximum allowed. Increase NBODMX in PHOMAIN if necessary.' ' ERR20:Two Bodies connected by 8 points have been found. This interface cannot resolve this configuration.' ' ERR22:The number of blocks found is more than the maximum allowed. Increase MAXBLK in PPHOE if necessary.' ' ERR23:Error renumbering the model. See the Q1 file for details.' ' ERR23:Error resolving Patch definition. See the Q1 file for details.' ' ERR25: PROPERTY FE PHOENICS must be selected.' ' ERR26:The number of ELEMENTS found is more than the maximum allowed. Increase MAXELE in PPHOE if necessary.' ' ERR27:The number of NODES found is more than the maximum allowed. Increase MAXNOD in PPHOE if necessary.*.'
If an error is found the GRID file, called <filename>.anl, will be created but no information will be written to the file.
Warnings
The following warnings may be produced :-
`WAR4:Body has an element type other than HE8. This is not recognised by PHOENICS. The body will be skipped. ' `WAR7:Body is the wrong type. Phoenics can only cope with SIX sided bodies. This body will be skipped.' `WAR15:A boundary condition has been defined on a line or point. This boundary condition will be ignored.' `WAR16:A contraint of type GEN or ELASTIC has been found. This has no meaning and will be ignored.' `WAR17:A load that is not FORCE, DISP,TEMP or HEAT has been found.This has no meaning and will be ignored.' ' WAR19:A patch that is not reqular has been found and will be ignored. See manual for more details' ' WAR21:Incorrrectly defined load. Value identifiers are :- 1-P1 2-U1 3-V1 4-W1 12-P2 22-U2 32-V2 42-W2'
If a warning condition is encountered, the message will be output,
and the interface program will continue
executing. The GRID file and Q1 file will be created.