Princeton University  

Return to Main Page


Ascend Acoustics CBM-170 SE

Click on links for full set of plots.


Horizontal directivity plots

Ascend Acoustics CBM-170 SE H Contour Plot

Full horizontal contour plot

Vertical directivity plots

Ascend Acoustics CBM-170 SE V Contour Plot

Full vertical contour plot

Directivity index plots

Ascend Acoustics CBM-170 SE Full Sphere DI Plot

Full-sphere directivity index plot

Constant directivity metrics plots

Ascend Acoustics CBM-170 SE Horizontal Polar XCorr Plot

Full horizontal NACC plot


Measurement notes:

  1. Date performed: 8 August 2014
  2. Nominal measurement distance: 1.6 meters
  3. Transducer type: dynamic
  4. Exponential sine sweep settings:
    • Frequency range: 20 Hz to 48 kHz
    • Duration: 5 seconds
  5. Impulse response window settings:
    • Type: Tukey (cosine fade-in, flat, cosine fade-out)
    • Duration: (0.5, 3, 0.5) msec
  6. Frequency resolution: 250 Hz
  7. Spectral smoothing: 1/24th octave
  8. Directivity index averaging range: 500 Hz to 20 kHz
  9. Alignment: Information not available.
  10. Additional notes: None.