| IDLNUM | Load identification number (Integer) |
| X,Y,Z | Co-ordinates of point of application of bending moment (Reals) |
| BX,BY,BZ | Components of the applied bending moment (Reals) |
| IUNT | Temporary file channel number (Integer) |
| IEXIT | Error condition (Integer) |
Use : To enter a single point bending moment for a single beam element. The load can be expressed in a local or global system, as long as all load types are entered in the same system.
| IEXIT | Meaning |
| 0 | Successful Call | |
| 32 | Current error must be cleared up first | |
| 129 | Error in writing to temporary file on unit (iunt) | |
| 146 | Beam load header expected | |
| 147 | None indicated or already done for current beam | |
| 149 | Distributed loads must precede point moments | |
| 211 | Invalid temporary file unit number (iunt) |