Error Messages Generated

 ERR 1: 
 STORE IS TOO SMALL FOR INTERFACE ELEMENT RESULTS
 INTERFACE ELEMENT RESULTS WILL BE INGNORED
 PLEASE CONTACT YOUR SUPPORT CENTRE FOR AN INCREASE

The number of INTER8, INTER9 and/or gasket element types in the model has exceeded the space available in the store array for their results. If results for these elements are not required this is not a problem. Results for all other elements will be transferred.



 ERR 2: 
 STORE IS TOO SMALL FOR INTERFACE ELEMENTS
 ANY MORE INTERFACE ELEMENTS WILL BE IGNORED
 PLEASE CONTACT YOUR SUPPORT CENTRE FOR AN INCREASE

The space required to store INTER8, INTER9 and/or gasket element types has been exceeded. If any more interface elements are found their results will be ignored. Results for the rest of the model will still be transferred.



 
 ERR 11 :
 ABAQUS FILE IS INCOMPLETE
 PLEASE REFER TO YOUR USER MANUAL FOR POSSIBLE CAUSES

This message is generated if an end of the ABAQUS file is detected that does not immediately follow a 2001 record. The most common cause of this message at the start of a run is a failure in opening the ABAQUS `.fil' file due to an incorrect file name being given for the `.fil' file. If this has occurred, a file of zero length with the name that the file opening routine expected will be created in the current directory.



 ** WARNING - NO RESULTS FOUND.

This message is issued when only model topology has been found in the ABAQUS `.fil' file. This happens either if no results were requested in the ABAQUS input file, or when the interface program found no results in the `.fil' file that it could process.



 ERROR 35 : RECORD SEQUENCE ERROR
 ERROR 36 : RECORD SEQUENCE ERROR

These errors are generated if the interface program cannot intepret the ABAQUS results file.



 ERROR 41 : ARRAY POINTER ERROR
 LIMIT EXCEEDED FOR GAUSS POINTS
 ERROR 43 : DATABASE ERROR   
 ERROR 44 : ILLEGAL EXIT CODE
 ERROR 45 : ILLEGAL EXIT CODE
 ERROR 46 : ILLEGAL EXIT CODE
 ERROR 47 : ILLEGAL EXIT CODE
 ERROR 48 : ILLEGAL EXIT CODE
 ERROR 49 : DATABASE ERROR
 ERROR 50 : DATABASE ERROR'

These errors are internal debugging errors. If any occur please contact your support centre.



   
 ERROR 42 : 
 INSUFFICIENT ARRAY SIZE
 FOR GAUSS POINTS. WILL TRY TO CONTINUE
 WITHOUT ALL THE GAUSS COORDINATES

This is caused by the number of gauss points being greater than the maximum permitted. As much of the model as possible will still be transferred. Please contact your support centre for an increase to this limit.



   
 ERROR 51:
 ERROR IN INPUT FILE
 -------------------
 NO GAUSS POINT COORDINATE DATA FOR THIS LOADCASE
 ALL GAUSS POINT CORDINATES FOR THIS LOADCASE WILL BE
 SET TO 0.0.'                                          
 TO OUTPUT GAUSS POINT COORDINATES THE ABAQUS INPUT'
 FILE MUST CONTAIN ONE OF THE FOLLOWING OUTPUT REQUESTS
                                                      
 *EL FILE, POSITION=INTEGRATION POINTS                 
 S,COORD                                               
 E,COORD                                               
                                                   
 OR                                                
                                                   
 *EL FILE, POSITION=INTEGRATION POINTS             
 S                                                 
 E                                                 
 COORD

The gauss point coordinates will be set to 0 for all gauss points with no coordinates.