Next: Example Runs
Up: ABAQUS-to-FEMVIEW
Previous: Whole Model Results Processed
ERR 1: STORE IS TOO SMALL FOR INTERFACE ELEMENT RESULTS INTERFACE ELEMENT RESULTS WILL BE INGNORED PLEASE CONTACT YOUR SUPPORT CENTRE FOR AN INCREASE
The number of INTER8, INTER9 and/or gasket element types in the model has exceeded the space available in the store array for their results. If results for these elements are not required this is not a problem. Results for all other elements will be transferred.
ERR 2: STORE IS TOO SMALL FOR INTERFACE ELEMENTS ANY MORE INTERFACE ELEMENTS WILL BE IGNORED PLEASE CONTACT YOUR SUPPORT CENTRE FOR AN INCREASE
The space required to store INTER8, INTER9 and/or gasket element types has been exceeded. If any more interface elements are found their results will be ignored. Results for the rest of the model will still be transferred.
ERR 11 : ABAQUS FILE IS INCOMPLETE PLEASE REFER TO YOUR USER MANUAL FOR POSSIBLE CAUSES
This message is generated if an end of the ABAQUS file is detected that does not immediately follow a 2001 record. The most common cause of this message at the start of a run is a failure in opening the ABAQUS `.fil' file due to an incorrect file name being given for the `.fil' file. If this has occurred, a file of zero length with the name that the file opening routine expected will be created in the current directory.
** WARNING - NO RESULTS FOUND.
This message is issued when only model topology has been found in the ABAQUS `.fil' file. This happens either if no results were requested in the ABAQUS input file, or when the interface program found no results in the `.fil' file that it could process.
ERROR 35 : RECORD SEQUENCE ERROR ERROR 36 : RECORD SEQUENCE ERROR
These errors are generated if the interface program cannot intepret the ABAQUS results file.
ERROR 41 : ARRAY POINTER ERROR LIMIT EXCEEDED FOR GAUSS POINTS ERROR 43 : DATABASE ERROR ERROR 44 : ILLEGAL EXIT CODE ERROR 45 : ILLEGAL EXIT CODE ERROR 46 : ILLEGAL EXIT CODE ERROR 47 : ILLEGAL EXIT CODE ERROR 48 : ILLEGAL EXIT CODE ERROR 49 : DATABASE ERROR ERROR 50 : DATABASE ERROR'
These errors are internal debugging errors. If any occur please contact your support centre.
ERROR 42 : INSUFFICIENT ARRAY SIZE FOR GAUSS POINTS. WILL TRY TO CONTINUE WITHOUT ALL THE GAUSS COORDINATES
This is caused by the number of gauss points being greater than the maximum permitted. As much of the model as possible will still be transferred. Please contact your support centre for an increase to this limit.
ERROR 51:
ERROR IN INPUT FILE
-------------------
NO GAUSS POINT COORDINATE DATA FOR THIS LOADCASE
ALL GAUSS POINT CORDINATES FOR THIS LOADCASE WILL BE
SET TO 0.0.'
TO OUTPUT GAUSS POINT COORDINATES THE ABAQUS INPUT'
FILE MUST CONTAIN ONE OF THE FOLLOWING OUTPUT REQUESTS
*EL FILE, POSITION=INTEGRATION POINTS
S,COORD
E,COORD
OR
*EL FILE, POSITION=INTEGRATION POINTS
S
E
COORD
The gauss point coordinates will be set to 0 for all gauss points with no coordinates.
Femsys Limited