Load Rheostat
The load control rheostat
is used in starting the engine and in controlling the load applied to
the engine by the dynamometer during steady state operation. The rheostat controls
the current to the field coils of the motor/generator, increasing this
current increases the torque of the device.
To start the Transparent
Engine: Set the Rheostat to 100, put the Load
Range switch in High, put the Field Switch in + , check that there are
no obstructions to engine rotation and that the ignition is turned on, then
move the Function
Switch to Start. Once the engine is running, move the function
switch to the Generator or Load position and move the Load Rheostat to
a position that maintains steady engine operation.
|
|