Next: Plotfile Format
Up: Error and Warning Conditions
Previous: Errors
[W1100:] Next name is the last in this sequence
[W1110:] 4-character names already active
[W1120:] 8-character names already active
[W1130:] Database file already exists
Please use another model name
[W1140:] Output file already exists
[W1150:] History file for this model already exists
[W1160:] No History file found for this model
New History file started
[W1170:] Unable to delete model History file
[W1180:] Invalid Model Name
Please use alphanumerics only
[W1190:] Reverting to 4-character names
Not advised for general use
[W1200:] Point is outside work-box
[W1300:] Node is outside work-box
A node has been defined which is outside the current limits of the FEMGEN work-box.
[W1400:] All analysis specific data will be deleted
A command has been issued that invalidates all analysis specific data.
[W1510:] Set not open
[W1520:] Duplicate points
[W1530:] Too many parts in command
[W1610:] No geometry to view
[W1620:] No mesh to view
[W1630:] Hidden requires mesh
[W1640:] Display list full
[W1710:] No geometry labels to output
[W1720:] No mesh labels to output
[W1730:] Not applicable to loadcase display
The command LABEL OPTIONS LOADS POSITION cannot be used when loads
are displayed by loadcase number.
[W1900:] Model must be saved before viewport plot
[W1910:] Viewport plot terminated
[W1920:] Command applies to post-processor only
[W2000:] No valid IGES types entered
[W2010:] Number of points set to 2
[W2020:] Number of points set to 99
Processing may be slow
[W2030:] Invalid number
[W2040:] Invalid string token in Iges file
Trying to continue processing
[W2050:] Model Tolerance not supplied in Iges header
[W2060:] Maximum absolute dimension not supplied in Iges header
[W2070:] Read Error in PATRAN file
[W2080:] No Points (Type 31) in PATRAN file
[W2090:] IGES file corrupted before the following line
[W2100:] Database is wrong type for required action
Possible problem with file extensions
It is not possible to perform the requested action on this
database. A reason may be that the database has been copied
and given the wrong file extension.
[W2110:] Geometry database already exists
[W2120:] No geometry database to update
[W2130:] Unable to interrogate directory
A problem has occurred when trying to find the contents of a
directory. This may be due to insufficient disk space.
[W2140:] No models in directory
If this is patently not true then a problem has occurred when trying to find the contents of a
directory. This may be due to insufficient disk space.
[W2150:] UNDO facility will be switched off
[W2170:] UNDO facility is switched off
[W2180:] Nothing to UNDO
[W2190:] UNDO facility is now switched off
[W2200:] Unable to open pick file
[W3100:] Facility not implemented
The requested operation has not yet been implemented.
[W3110:] Facility not licenced
The requested facility has not been licenced.
Contact your support centre for licencing details.
[W3120:] Mesh too large for restricted version
The model is too large for the licenced version of the program.
[W3130:] Facility not implemented for IJK models
The requested operation is not available for models defined in IJK notation.
[W3140:] No match for this synonym
A synonym has been specified which does not exist.
[W3150:] Synonym match exists already
New synonym will replace old
A new synonym definition has been specified for a synonym
that already exists. The new definition will replace the old.
[W3160:] Synonym substitution too long
A command synonym, when expanded, exceeds 80 characters.
[W3170:] Maximum number of synonyms exceeded
The maximum number of synonyms that may be defined is 300.
[W3180:] This is a priority synonym
An attempt has been made to redefine a priority synonym. This
is an illegal operation.
[W3190:] Cannot colour an edge view of this IJK model.
All mesh will be drawn
The requested operation is not available for models defined in IJK notation.
[W3200:] User interrupt detected.
The user has issued a program interrupt.
[W3210:] Archive file already exists.
[W3220:] Session continues but will not be logged
No command logging will take place.
[W3230:] Unable to open log file
Do you want to stop the program?
It has not been possible to open the file to be used for command logging.
[W3240:] Unable to open new plotfile
It has not been possible to open the file to be used for plotting.
[W3250:] Facility not available for graphs
An operation has been requested that is inappropriate for graphs.
[W3260:] Not possible when in multi-viewport
Whilst in the multi-viewport mode of operation a command has been issued
that can only be executed whilst in the single viewport mode of operation.
[W3270:] Minimum pagelength is 10 lines
A command has been issued which attempts to set the page length for
printed output at less than the permitted minimum of 10 lines.
[W3290:] Only 3 character sizes supported
Only 3 character sizes are supported for the FEMGV neutral
plot file format.
[W3300:] Appending to existing archive file
[W3310:] Model has no mesh data
[W3320:] Model has no nodal axis-system data
[W3330:] Model has no element axis-system data
[W3340:] Model has no gauss point axis-system data
[W3350:] Model has no gauss point data
[W3360:] Axis system will be assumed from topology
[W3370:] Unable to open log file
The file used to keep a log of the command input cannot be opened.
[W3380:] Model has no constraints data
[W3390:] Model has no externals data
[W3400:] Model has no MPC data
[W3410:] Logarithmic scale not supported for
moment or force diagrams or beam graphs
Log scales are not available with shear force or bending moment diagrams
or with beam graphs, so linear scales have been reselected.
[W3420:] Subset of IJK regular model is current.
Archive will be in expanded FE form
A request to archive a subset of a model defined in IJK notation
has been made. It is not possible to define the subset in IJK
terms so the subset will be archived in expanded FE form.
[W3430:] Too many loadcases
The maximum number of loadcases that can be processed by a command
has been exceeded.
[W3440:] Deform attribute not found
The attribute specified for use in deforming the model cannot be found.
[W3450:] Results Range Material filter is on
The option to request results only for a specified material is
currently active. This filter may prevent there being
any appropriate result values for display.
[W3460:] Results Range Surface filter is on
The option to request results only for a specified surface is
currently active. This filter may prevent there being
any appropriate result values for display.
[W3470:] Cannot transform this results type
It is not possible to apply a transformation to the currently selected results.
[W3480:] Datum node is multi-material
Values for 1st material used for datum
A node specified for use as a datum has result values for more than
one material. The result values for the 1st material will be used
for the datum.
[W3490:] Model view mode is not full mesh
Results data archived may be incomplete
A request to archive results data has been made when the current
VIEW mode is not full mesh. Archiving of results is
sensitive to view mode and only results for those nodes/elements
visible in the current view will be archived.
[W3500:] Frames will be mapped
Too many frames have been specified for an animation sequence. Only
the first specified, up to the permitted maximum, will be used.
[W3510:] Max of 20 shapes. First 20 processed
A program maximum has been exceeded - 20 shapes only will be processed
[W3520:] Minimum number of digits is 1
Significant digits set to 1
The number of significant digits can never be set to less than 1.
[W3530:] Maximum number of digits is 7
Significant digits set to 7
The number of significant digits can never be set to more than 7.
[W3540:] Unresolvable intersections
[W3550:] Unable to create picture. View cancelled
[W3560:] Non-existent nodes will be ignored
A list containing non-existent nodes has been specified.
[W3570:] Non-existent elements will be ignored
A list containing non-existent elements has been specified.
[W3580:] Some results values not found
Some results requested for presentation were not found. Check that any
node or element numbers specified are viable.
[W3590:] Plotfile already exists
[W3600:] Plane will be perturbed
When defining a cross section through a 3-D model no elements
have been intersected by the defined plane, so a small perturbation
will be applied to the plane.
[W3610:] No elements intersected
When defining a cross section through a 3-D model no elements
have been intersected by the defined plane.
[W3620:] No elements visible
An attempt has been made to use the cursor to pick an element
but no elements are visible.
[W3630:] No nodes visible
An attempt has been made to use the cursor to pick a node
but no nodes are visible.
[W3640:] Internal buffer is full
The line defined will be processed
Insufficient internal space is available to store the last node or
element picked with the cursor when defining a line through the model.
The line defined so far will be used.
[W3650:] Internal buffer is full
Insufficient internal space is available to store the last item picked
with the cursor. The maximum number of items that can be picked is 200.
[W3660:] Named set is already open
[W3670:] Internal buffer is full
Line will be truncated
Insufficient internal space is available to store the full definition
of the line, and so the line will be truncated at some point.
[W3680:] This is the Student Version
Maximum of 100 elements exceeded
The model is too large for the licenced version of the program.
[W3690:] Deform mode is not currently active
[W3700:] Invalid test for this element type
[W3710:] Weights do not add to unity for BE3
[W3720:] Weights do not add to unity for TR3
[W3730:] Weights do not add to unity for QU4
[W3740:] Weights do not add to unity for TR6
[W3750:] Weights do not add to unity for QU8
[W3760:] Weights do not add to unity for QU9
[W3770:] Weights do not add to unity for PE6
[W3780:] Weights do not add to unity for HE8
[W3790:] Weights do not add to unity for PE15
[W3800:] Weights do not add to unity for HE16
[W3810:] Weights do not add to unity for HE20
[W3820:] Weights do not add to unity for HE27
[W3830:] Quality values must be positive
[W3850:] Model deform is current.
Archived co-ordinates will be deformed
[W3860:] No pointer defined
An attempt has been made to delete or reposition a pointer when
no pointers exist.
[W3870:] Previous pointer will be overwritten
The maximum number of pointers that can be defined is 6. If
more than the maximum are defined then the last successfully
defined will be replaced by the new pointer.
[W3880:] No text defined
An attempt has been made to delete or reposition a text item when
no text items exist.
[W3890:] Previous text will be overwritten
The maximum number of text items that can be defined is 6. If
more than the maximum are defined then the last successfully
entered will be overwritten by the new text item.
[W3900:] No valid results for presentation
Either no results found or values
outside current results range settings
An attempt to present results has failed because either no
results were found for the elements or nodes in question, or
the available results have rejected because of other filters
on the results that have be applied via the RESULTS RANGE
command.
[W3910:] Too many gauss-points
A maximum of 27 Gauss points per element is permitted.
[W3920:] List too long. Will use max allowed
Too many nodes or elements have been specified in a list. The
maximum allowed will be used.
[W3930:] No range of nodes specified
No range of nodes has been specified for the current
presentation command.
[W3940:] No range of elements specified
No range of elements has been specified for the current
presentation command.
[W3950:] No results values found in range
A range of results values has been specified but no result values
are within the range.
[W3960:] Not a colour device
A command requiring the use of colour has been requested for
a graphics device that has no colour capability.
[W3970:] Colours will be mapped
The specified command requires more colours than are available
on the current graphics device. The command will be mapped
to the available colours.
[W3980:] Edge contours unavailable
Device does not support colour lines
The graphics device does not have a line colour capability.
[W3990:] Filled contours unavailable
Device does not support colour fill
The graphics device does not have a fill colour capability.
[W4000:] User interrupt detected
The user has issued a program interrupt.
[W4010:] No constraints to show for this view
Presentation is sensitive to VIEW command
[W4020:] No externals to show for this view
Presentation is sensitive to VIEW command
[W4030:] Reference made to local system
But model has no local system data
[W4040:] Reference made to non-existent local system
[W4050:] No result axis systems to show for this view
Presentation is sensitive to VIEW command
[W4060:] Y and Z-axes are not displayed for beams
[W4070:] Beams have been switched off from hidden views
[W4080:] Fattening factor too large
[W4090:] Fattening factor too small
[W4100:] This loadcase does not exist
A loadcase specified in a prompt sequence does not exist.
[W4110:] Loadcase does not have required attribute
A loadcase specified in a prompt sequence does not have
the required results attribute.
[W4120:] Incorrect value
An incorrect value has been entered in a prompt sequence.
[W4130:] Incorrect step number
An incorrect value for a loadcase step number has been entered
in a prompt sequence.
[W4140:] This loadcase attribute is results data
It cannot be used with load data
[W4150:] This loadcase attribute is load data
It cannot be used with results data
[W4160:] No source loadcases specified
[W4170:] Deformation values are 0.0
[W4180:] Deform mode remains active
[W4190:] This loadcase attribute is percentage data
It is therefore unsuitable
[W4200:] Block number or IJK range not found
[W4210:] Block number must be positive
[W4220:] IJK range numbers must be positive
[W4230:] IJK range not found
[W4240:] Block number not found
[W4250:] Only one direction may have an n1 TO n2 range
Default is 1 to max for unspecified directions
[W4260:] K range not valid for 2D models
[W4270:] Model has no IJK definition
Commands using IJK notation have been specified but there is no
IJK definition of the model.
[W4280:] Outline edges not supported for this view
of this IJK model. All mesh will be drawn
[W4290:] Current attribute not available in this loadcase
[W4300:] No results presentation active
[W4310:] Cannot label this result type
[W4320:] Cannot label this result presentation
[W4330:] No enumerative results labels found
[W4340:] Cannot label results on this view
[W4350:] Line contours are unsuitable
Inappropriate results type or view
[W4360:] No variation in results value
[W4370:] Combining certain data types is meaningless
This general warning message is issued during the RESULTS CALCULATE COMBINE
command to remind users that the combination of certain data types such as
Von Mises stresses is meaningless.
[W4380:] Viewdata database already exists
[W4390:] No viewdata database to update
[W4400:] No analysis code integrated
[W4410:] Valid only if gauss point co-ordinates are undeformed
The requested calculation is valid only if the gauss point co-ordinates
are in their undeformed state.
[W4420:] Variation in number of materials per surface at nodes
Averaging only for materials common to all surfaces
Some nodes show a variation in the number of materials from one surface
to the other and nodal averaging is only performed on the materials
that are common to all surfaces.
[W4430:] Only material discontinuities are considered
Other types of discontinuity (physical, geometric) are not taken
into account when an averaging calculation is performed.
[W4440:] Variation in number of materials per surface at nodes
Calculation only for materials common to all surfaces
Some nodes show a variation in the number of materials from one surface
to the other and the calculation is only performed on the materials
that are common to all surfaces.
[W4450:] No calculation performed for some materials
One or more material identification number(s) was not recognized and
no percentage difference is performed for this material.
Contact support centre.
[W4460:] Facility not available for IR path grid
[W4470:] Dummy IR path calculation being used
[W4480:] Cannot present results: presentation deactivated
Presentation of results is turned off until another command is given
[W4490:] Cannot integrate these results
Results integration cannot proceed
[W4500:] Attribute already combined
During the combination of ALL results attributes, one attribute was found to
have already been combined in the requested combination loadcase.
[W4510:] Attribute already scanned
During a scan of ALL results attributes, one attribute was found to have
already been scanned in the requested scan loadcase.
[W4520:] Attribute contains enumerative components
A specified attribute was found to contain enumerative components.
[W4530:] Attribute contains complex components
A specified attribute was found to contain complex components.
[W4540:] This loadcase is a scan loadcase and is unsuitable
The specified loadcase is a scan loadcase and can therefore not be used.
[W4550:] Scan loadcase selected
A selected loadcase is a scan loadcase which is unsuitable for calculations.
[W4560:] Attribute contains too many components to scan
An attribute must have no more than 10 components if it is to be scanned.
[W4570:] Attribute contains material independent results
A selected attribute is unsuitable for the requested command because it
contains material independent results.
[W4580:] Scanned results are for different numbers of surfaces
Surface numbers may therefore be misleading
A surface scan has been performed successfully but over differing numbers of
surfaces. Therefore the integers showing the surfaces the results came from
may be misleading. For example, if a model has some nodes with results for 3
surfaces and other nodes with results for 5 surfaces, then scan output results
labelled as being found for surface "3" will mean for the bottom surface for
nodes with results for only 3 surfaces and for the middle surface for nodes
with results for 5 surfaces.
[W4590:] Some scanned results are for only one surface
A surface scan has been performed successfully but some of the scanned results
were single surface results.
[W4600:] Scanned results are for only one surface
A surface scan has been performed successfully but the scanned results were
only single surface anyway.
[W4610:] Surface selection inappropriate for material independent results
A surface has been selected for results which are single surface results.
[W4620:] Surface selection inappropriate for single surface results
A surface has been selected for results which are single surface results.
[W4630:] Surface selection ignored
The selection of a surface is inappropriate and has been ignored.
[W4640:] Axes swap not suitable for this diagram
The axes on a shear force or bending moment diagram can not be swapped.
[W4650:] Current attribute already in stack
The current selection of results attribute, component and optionally calculation
was not added to the results stack because it already had been.
[W4660:] There are no OUTLINE edges in this model
Cannot draw this edge representation
[W4670:] There are no OUTLINE edges in this model set
Cannot draw this edge representation
[W4680:] Nearest section point has no close node
[W4690:] Some section points have no close node
[W4700:] Weights do not add to unity for QU12
[W4710:] Weights do not add to unity for TR9
[W4720:] Weights do not add to unity for TR15
[W4730:] Weights do not add to unity for BE4
[W4740:] Weights do not add to unity for BE5
[W4750:] Weights do not add to unity for PE24
[W4760:] Weights do not add to unity for HE32
[W4770:] Weights do not add to unity for TE4
[W4780:] Weights do not add to unity for TE10
[W4790:] Weights do not add to unity for TE16
Femsys Limited