next up previous contents
Next: Topology and Coordinates Up: PAFEC-to-FEMVIEW Previous: Program Termination

Program Capabilities

This chapter gives details of the the principle capabilities and operation of the interface program

A table summarising the Pafec elements handled and the types of results processed is given in Table 2.1. Note that a `+' indicates that an orthotropic element with an equivalent topology exists.


 
Element Femview Displacements/ Temperatures Stresses
Number Type Eignevectors Beam Nodal Element
30100 11 Yes No No No No
34000 11 Yes No No No No
34100 11 Yes No Yes No No
34200 11 Yes No Yes No No
34300 11 Yes No No No No
34400 11 Yes No No No No
34500 11 Yes No Yes No No
34600 11 Yes No Yes No No
34700 11 Yes No Yes No No
34800 12 Yes No No No No
34900 12 Yes No No No No
39800 11 No Yes No No No
42120 11 Yes No No No No
42130 12 Yes No No No No
43310+ 12 Yes No No No No
36100+ 7 Yes No No Yes Yes
36110+ 8 Yes No No Yes Yes
36200+ 9 Yes No No Yes Yes
36210+ 10 Yes No No Yes Yes
36610+ 10 Yes No No Yes Yes
36620+ 8 Yes No No Yes Yes
36630+ 9 Yes No No Yes Yes
36640+ 7 Yes No No Yes Yes
39100+ 7 No Yes No No No
39110+ 8 No Yes No No No
39200+ 9 No Yes No No No
39210+ 10 No Yes No No No
41320+ 7 Yes No No Yes Yes
43110+ 8 Yes No No Yes Yes
43210+ 10 Yes No No Yes Yes
44110+ 8 Yes No No Yes Yes
44200+ 9 Yes No No Yes Yes
44210+ 10 Yes No No Yes Yes
45110+ 8 Yes No No Yes Yes
45210+ 10 Yes No No Yes Yes
46110 8 Yes No No Yes Yes
46210 10 Yes No No Yes Yes
37100+ 1 Yes No No Yes Yes
37110+ 4 Yes No No Yes Yes
37200+ 2 Yes No No Yes Yes
37210+ 5 Yes No No Yes Yes
37300+ 3 Yes No No Yes Yes
37310+ 6 Yes No No Yes Yes
39600+ 2 Yes No No Yes Yes
39610+ 5 Yes No No Yes Yes
39700+ 1 Yes No No Yes Yes
39710+ 4 Yes No No Yes Yes
Table 2.1: Elements and Results Processed



 
next up previous contents
Next: Topology and Coordinates Up: PAFEC-to-FEMVIEW Previous: Program Termination

Femsys Limited
8/18/1999